Readings look too low (always near 0%)
- Push the probe deeper so the moisture contacts are fully covered — exposed contacts read as dry air.
- Confirm the soil isn’t pulling away from the probe after drying out. Press the soil back around the probe.
- Re-run the wet point in Calibrate a sensor after watering.
Readings look too high (always near 100%)
- Make sure the probe isn’t sitting in a pocket of standing water at the bottom of the pot.
- Check drainage — a pot without drainage holes stays saturated and reports high indefinitely.
- Re-run the dry point in Calibrate a sensor with the probe clean and dry.
Readings are stuck or not updating
- Confirm the sensor is still reporting on the soil moisture dashboard — a stale timestamp points to a connectivity issue, not accuracy.
- Verify the sensor is well matched to the pot size. See Sensor types for probe-length guidance.
Still off after recalibrating? The probe contacts may be corroded. Wipe them with a dry cloth, and replace the sensor if a thin film remains.